(1) When fixing the switch body, use M2 small screws on the smooth surface with a torque of 0.098N-m or less. In addition, in order to prevent the screw from loosening, it is recommended to use a washer at the same time
(2) Please note that the action body should not directly exert force on the button or the exciter in the free state, and the button should exert force in the vertical direction during use.
(3) The operation setting after operation is based on 70 percent or more of the O.T. value. In the case of a switch, do not set the action body at the action limit position to avoid the opening and closing, over-
Stroke shortens life.
(4) In the case of hand soldering, please use an electric temperature of 320 degree with temperature adjustment to complete the operation within 3 seconds, and be careful not to apply force to the terminal part during the operation.